How does an electric regulating valve control various factors of pipeline media?


Electric regulating valves use a power supply to drive an electric actuator, which in turn drives the valve to throttle. They are important final control elements in industrial automation process control. As the automation level in the industrial field becomes increasingly higher, they are being increasingly used in various industrial production fields. Compared with traditional pressure regulating valves, electric regulating valves have obvious advantages: electric single-seat regulating valves are energy-saving and environmentally friendly, and are easier and more convenient to install.

Electric regulating valves receive signals from industrial automation control systems to drive the differential pressure regulating valve series to change the cross-sectional area between the valve core and valve seat, controlling the flow rate, temperature, pressure, and other process parameters of the pipeline medium, thereby achieving automated regulation.

The electric actuator of the electric sleeve regulating valve is an electronic integrated structure, which contains a servo amplifier. Inputting control signals and power supply can control the valve opening to adjust pressure, flow rate, liquid level, temperature, and other process parameters. Note: To ensure that the regulating valve can operate normally during startup and that the system runs safely, before installation, the nameplate markings on the new valve should be checked to ensure they match the design requirements.

Thirdly: If a major overhaul is performed on a regulating valve in the original system, in addition to verifying the above items, the sealing of the packing gland and connections of the old valve should also be checked.

Fourthly: In the field use of regulating valves, many problems are often not caused by the quality of the regulating valve itself, but by improper installation and use of the electric regulating valve, such as improper installation environment, installation location and direction, or unclean pipelines.

First: Regulating valves are field instruments, requiring an ambient temperature of -25~60℃ and a relative humidity of 95%. If installed outdoors or in high-temperature environments, waterproof and cooling measures should be taken. In places with vibration sources, keep away from the vibration source or add vibration-damping measures.

Second: Electric regulating valves should generally be installed vertically. In special cases, they can be installed at an angle. If the angle is large or the valve itself is too heavy, supporting components should be added for protection.

Thirdly: The pipeline for installing the regulating valve should generally not be too high from the ground or floor. When the pipeline height is greater than 2m, a platform should be set up as much as possible to facilitate operation of the handwheel and maintenance.

Fourthly: Before installing the electric regulating valve, the pipeline should be cleaned to remove dirt and welding slag. After installation, to ensure that no impurities remain in the valve body, the valve should be cleaned again. When the medium is introduced, all valves should be opened to prevent impurities from getting stuck. After using the handwheel mechanism, it should be restored to its original neutral position.

Fifthly: In order to allow the production process to continue in the event of a failure or maintenance of the electric regulating valve, a bypass pipeline should be added to the regulating valve.