What are the differences between globe valves and gate valves?
Valves are control components in fluid conveyance systems, with functions including shutoff, regulation, flow guidance, backflow prevention, pressure stabilization, flow splitting, or pressure relief via overflow. Valves used in fluid control systems range from simple shutoff valves to various valves used in highly complex automated systems, with a wide variety of types and specifications.
Shutoff valves, gate valves, butterfly valves, check valves, and ball valves are indispensable control components in various piping systems today. Each valve differs in appearance, structure, and even functional use. However, globe valves and gate valves share some similarities in appearance and both have the function of shutoff in pipelines, so many people unfamiliar with valves often confuse the two. In fact, if you observe carefully, the differences between globe valves and gate valves are quite significant.
1. Structural Differences
Space constraints during installation should be considered when selecting a valve. Gate valves rely on media pressure to tightly close against the sealing surface, achieving a leak-proof effect. When opening and closing, the valve stem and valve seat sealing surfaces are always in contact and rubbing against each other, so the sealing surfaces are prone to wear. When the gate valve is nearly closed, the pressure difference between the upstream and downstream sides of the pipeline is large, causing more severe wear on the sealing surfaces.
2. Working Principle
When opening and closing a globe valve, it is a rising stem type, meaning that when the handwheel is turned, the handwheel rotates and moves up and down with the stem. For a gate valve, turning the handwheel causes the stem to move up and down, while the handwheel itself remains stationary. The flow rates are different; gate valves require full opening or full closure, while globe valves do not. Globe valves have specified inlet and outlet directions; gate valves do not have inlet and outlet direction requirements.
In addition, gate valves only have two states: fully open or fully closed. The gate plate has a large opening and closing stroke, and the opening and closing time is long. The valve plate movement stroke of a globe valve is much smaller, and the valve plate can stop at a certain point during movement for flow regulation. Gate valves can only be used for shutoff and have no other functions.
The structure of a gate valve is more complex than that of a globe valve. In terms of appearance, for the same diameter, a gate valve is taller than a globe valve, and a globe valve is longer than a gate valve. In addition, gate valves are divided into rising stem and non-rising stem types. Globe valves do not have this distinction.
3. Performance Differences
Globe valves can be used for shutoff and flow regulation. Globe valves have relatively large fluid resistance and are more difficult to open and close, but because the valve plate is a short distance from the sealing surface, the opening and closing stroke is short.
Because gate valves can only be fully open or fully closed, the fluid resistance in the valve body passage is almost zero when fully open, so the opening and closing of gate valves is very easy, but the distance between the gate plate and the sealing surface is far, and the opening and closing time is long.
4. Installation and Flow Direction
Gate valves have the same effect in both flow directions and do not have inlet and outlet direction requirements; the medium can flow in both directions. Globe valves must be installed strictly according to the direction indicated by the arrow on the valve body. There is a clear regulation regarding the inlet and outlet direction of globe valves; China's "Three Standardizations" regulations stipulate that the flow direction of globe valves should always be from top to bottom.
Globe valves have a low inlet and high outlet, and the pipeline is clearly not on the same horizontal plane. The flow path of a gate valve is on a horizontal plane. The stroke of a gate valve is larger than that of a globe valve.
From the perspective of flow resistance, the flow resistance of a gate valve is small when fully open, while the flow resistance of a globe valve is large. The flow resistance coefficient of an ordinary gate valve is about 0.08~0.12, the opening and closing force is small, and the medium can flow in two directions. The flow resistance of an ordinary globe valve is 3-5 times that of a gate valve (WeChat Official Account: Pump Manager). It must be forcibly closed to achieve sealing. The valve stem of a globe valve only contacts the sealing surface when it is fully closed, so the wear on the sealing surface is small. Due to the large flow resistance, globe valves that require actuators should pay attention to the adjustment of the torque control mechanism.
There are two ways to install a globe valve: one is that the medium can enter from below the valve stem. The advantage is that when the valve is closed, the packing is not under pressure, which can extend the service life of the packing and allows for packing replacement when the pipeline in front of the valve is pressurized; the disadvantage is that the driving torque of the valve is larger, about twice that of the top-inlet type, and the axial force on the stem is large, making the stem prone to bending. Therefore, this method is generally only suitable for small-diameter globe valves (DN50 or less), and globe valves larger than DN200 generally use the top-inlet method. (Electric globe valves generally use the top-inlet method.) The disadvantages of the top-inlet method are the opposite of the bottom-inlet method.
5. Sealing
The sealing surface of a globe valve is a small trapezoidal side of the valve stem (depending on the shape of the valve stem). Once the valve stem falls off, it is equivalent to the valve closing (if the pressure difference is large, it will not close tightly, but the backflow prevention effect is still good). A gate valve relies on the side of the gate plate to seal, and the sealing effect is not as good as that of a globe valve. If the valve stem falls off, it will not be equivalent to the valve closing like a globe valve.